Seattle University
  • Calendar
  • Site Index
  • Directories
  • Contact
  • Support SU
More Options
  • Report a Problem
  • Give Us Feedback
  • Search SU
  • Where do you need to go?
    • Academic Affairs
    • Professional and Continuing Education
    • Catalog
    • Core Curriculum
    • Diversity Statement
    • Global Learning
    • Health and Personal Wellness
    • Mission and Ministry
    • Nondiscrimination Policy
    • Summer Programs
    • Visit Campus
    • Facilities Services
    • Schools and Colleges
    • Albers School of Business and Economics
    • College of Arts and Sciences
    • College of Education
    • College of Nursing
    • College of Science and Engineering
    • Matteo Ricci College
    • School of Law
    • School of Theology and Ministry
    • Departments
    • Alumni
    • Athletics
    • Bookstore
    • Conference and Event Services
    • Housing and Residence Life
    • Human Resources
    • Information Technology
    • Lemieux Library
    • Marketing Communications
    • Office of Research Services
    • Public Safety
    • Recreational Sports
    • Registrar
    • Student Financial Services
    • Online Services
    • SUOnline
    • Email
    • Angel
    • MySU

Site Map | Contact | Directory

College of Science and Engineering
  • About the College
  • Areas of Study
  • Advising
  • Transfer Students
  • Project Center
  • Outreach
  • Donate Now

Department of Electrical & Computer Engineering

  • About
  • Electrical Engineering with Computer Engineering Specialization
  • Electrical Engineering
  • Senior Design
  • Transfers
  • Student Clubs
  • Laboratory
  • ECE TV
  • Careers/Recruitment

 2010-11 ECE Electives      
PDF Download
       

  

70yearssuee-shad 

EE-Facebook 

Announcements

New Student Retreat 
An opportunity for first year and transfer students to get away for a weekend in order to meet new students, reflect on how the year is going so far, and spend time in the beautiful Pacific Northwest. Get future dates 

  

Society of Hispanic Professional Engineers 
Join SHPE and take advantage of its Career Fair.
Officers  

  

The electrical engineering program is accredited by the Engineering Accreditation Commission of ABET http://www.abet.org/  

Student Software

  • Microsoft MSDNAA  
  • e-academy.com  
  • Design Software  
  • School World  
  • Cadence Acknowledgement  

SU Campus Video

 

Best Colleges 1 

MyCampusVideo-1 

 

 

 

 
Electrical & Computer Engineering Department 
Seattle University
901 12th Ave. Bannan 209
Seattle, WA 98122-1090

TEL: 206.296.5970
FAX: 206.296.5962

  

College of Science and Engineering > Electrical & Computer Engineering > Laboratory

Oscilloscope Screen Capture & Printing Software

To setup the oscilloscope and software, select the appropriate model below for Instructions

Agilent Oscilloscope:        7012B     |     54621A     |     54603B & 54645D 

 

Agilent IntuiLink Data Capture   

Agilent IntuiLink Data Capture is a software solution that captures waveform and/or data from the test and measurement instrument to the PC.

Agilent IO Control (IO Libraries Suite) 

The Agilent IO Libraries Suite is a collection of libraries that give you the ability to use the oscilloscope within the Agilent IntuiLink Data Capture program and custom test and measurement programs. The Suite also includes the utility IO Connection Expert to help you quickly and easily check the connection of your instruments to your PC. . 
 


 

Agilent 7012B 2 Channel 100Mhz Oscilloscope

Agilent Oscilloscopes For Electrical Engineer Schools

 

Agilent IntuiLink Data Capture Software

a) To run IntuiLink see the start menu example below.

IntuiLinkStart11 

How to capture the scope screen to the PC

a) New users to a workstation must have first complete the software setup one time -see section below: Software Setup for Model DSO7012B 

b) If you have completed the software setup prior begin the screen capture by selecting the [Get Data] icon.

Getimage1 

c) The oscilloscope will display "Remote operation in progress. Please wait." 

d) Done

 

Software Setup for Model DSO7012B

Setup IntuiLink Data Capture Software.

a) From the [Instrument] menu select [Agilent 7000 Series] 

 Electrical_Engineering_School_Oscilloscope_1 

 

 b) Select the [Set I/O] tab then press the [Find Instruments] button

Electrical Engineering Schools Oscilloscope Step 2 

 

c) From the ports available select the port that begins with the "USB" identifier. 

  • If no USB port is displayed try  power cycling the oscilloscope and restart IntuiLink software. This often works.

d) Press the [Identify Instrument(s)] button.
 
Electrical Engineering Schools Oscilloscope Step 3 

  

 e) Press the [OK] button
 
Computer Engineers Love Oscilloscopes 

 

f) Press the [OK] button
 
Computer Engineers Love Oscilloscopes -2 

 

Get Screen Image & Get Waveform Data 

IntuiLink is capable of downloading both the oscilloscope screen image and the waveform in numerical data (useful for spreadsheets and data analysis).

g) For faster capture uncheck the field [Get waveform data] to download only the screen image if you don't need the numerical data.

h) Press the [OK] button
 

Electrical Engineering College Oscilloscope Step 6 

 

i) The oscilloscope will display [Remote operation in progress. Please wait.]

j) You can now save to file, print, or copy-n-paste the image.

k) When printing check the option to [Fit to page] to scale image to entire page.
 

l) Done 

 

Printing Options

 
 Fit to Page  &  1 up: Prints to one full page
 Electrical Engineering Students Oscilloscope Step 1   Electrical Electronics Engineering Scope Print -1 
 
  Fit to Page  &  2 up: Prints to 1/2 page
 Electrical Engineering Students Like to Print Sometimes   Electronics Education Best for Printing 
 
   Fit to Page  &  4 up: Prints to 1/4 page
 Electrical Engineering Department Printing Opton 3   Electrical Electronics Engineering Scope Print -7
 

 
  
 

 


 

54621A 2-Channel 60 MHz Oscilloscope
 Oscilloscope-BSEE-54621A

IntuiLink Data Capture for Model 54621A 

a) To run IntuiLink see the start menu example below.

 IntuiLinkStart11
 

How to capture the scope screen to the PC

a) New users to the workstation must have first completed the software setup once - See section below: Software Setup for 54621 

b) If you have completed the software setup prior begin the screen capture by selecting the [Get Data] icon.

Getimage1 

c) The oscilloscope will display "Remote operation in progress. Please wait." 

d) Done

 

If any errors please proceed below. 

a) New users to the workstation will have to run the software setup below once.

b) Check that the RS232 cable is connected from the PC to the oscilloscope.

d) Try power cycling the scope and restart IntuiLink software. This often works.

 

Software Setup for model 54621

Setup IntuiLink Data Capture Software for model 54621

a) From the [Instrument] menu select [54620/40-Series]   (for oscilloscope models 54603B and 54645D only select 54600-Series)

ECE Lab  

IntuiLink is capable of downloading both the oscilloscope Screen Image and the Waveform Data (useful for spreadsheets and data analysis).

b) Uncheck field [Get waveform data] to download only the Screen Image for faster capture.

ECE Lab 

c) Select the [Set I/O] tab then [Find Instruments] button

    6-SetIO_g 

 d) Select [Identify Instrument(s)] button

ECE Lab  

e) Set all RS232 settings as show below

Baud Rate = 57600 for oscilloscope model 54621A  (or 19200 for models 54603B and 54645D)
Note Parity, Size, and HandShake settings that must be set appropriately! 

   8-baud-57600 

f) The instrument found should display as shown below.

g) Pressthe [Connect] button

ECE Lab 

h) Instrument should be displayed as "Connected". Press the [Close] button.

ECE Lab 

i) Press the [OK] button

54621A-OK 

j) Oscilloscope will display [Remote operation in progress. Please wait.]
 

 54621A_0 

k) When download completed, screen will be displayed within IntuiLink.

What Electrical Engineers Can Do -College 

l) You can now save, print, or copy the screen capture image.

J) When printing you can set it to scale to fit the entire page in the print menu. 

J) Done 

 

If any errors please proceed below. 

a) Check that the RS232 cable is connected from the PC to the oscilloscope.

b) Try power cycling the scope and software. That sometime works.

 

Check Oscilloscope RS232 Settings for Model 54621A  

The oscilloscope RS232 settings must match both the IO Connection Expert and IntuiLink Data Capture settings.

a) Select oscilloscope [Utility] button then select I/O.

54621A_UtilityMenu-IO 

 b) Set the correct Baud Rate and DTR setting for the connected oscilloscope.
Baud Rate = 57600 for oscilloscope model 54621A  (or 19200 for models 54603B and 54645D)
Handshaking = DTR for all oscilloscope.
 

 
54621A_IOMenu 

 

c) Still not working? Try power cycling the scope and software. That often works.

d) Try the setup again or proceed below.

 

Check Agilent IO Control setup 

a) Click on the IO icon in your taskbar at the bottom right of your screen.

IOControlIcon2 

b) Select [Agilent Connection Expert] and wait one minute for application to start.

ConnectionExpertStart 

c) Close any welcome screens

d) Expand COM1 port to check instrument attached. Green check marks (as shown below) indicate proper communication.

54621A-COM1 

 

If the wrong instrument is displayed or there are red x-marks indicating an error, complete any of the following tests: 

(1) Check RS232 Cabling from PC to Oscilloscope.
(2) Power cycle the oscilloscope and wait until it is fully powered up and has completed self-tests, then
(3) Select Refresh All to check again.

Complete Only If Needed:
(4) Select any instrument shown being attached to COM1 so that it is highlighted 
(2) Select Delete to delete instrument
(3) Select COM1 so that it is highlighted
(4) Check RS232 settings 
Baud rate = 19200 for all oscilloscope models.
Flow Control and all other RS232 settings should display as shown above.

(5) Select Add Instrument
(6) Select Auto-identify.

If errors, check cabling and oscilloscope RS232 settings in the sections above.

 


 

54603B 2-Channel 60 MHz Oscilloscope
54645D 2-Channel 100-MHz 200-MSa/s Mixed Signal Oscilloscope

 

 1. IntuiLink Data Capture Setup (for model 54603B and 54645D) 

a) To run IntuiLink see the start menu example below.

 IntuiLinkStart11 

b) If the Welcome Box opens: Select √ check mark field "Do not show this dialog again" and close the box.

ECE Lab 

c) Select Get Data icon to begin capture.

Getimage1 

d) Oscilloscope will display Remote operation in progress. Please wait. 

e) Done
 

 

If any errors please proceed below to check setup. 

a) Try power cycling the scope and restart IntuiLink software. That often works.

b) New users to a computer will have to run the setup once.

 

 

 
To Setup IntuiLink Data Capture Software
 

a) From the Instrument menu select 54600-Series for models 54603B and 54645D (or 54620/40-Series for model 54621A)  

54603b 

 b) Select Get Waveform Data tab

IntuiLink is capable of downloading both the oscilloscope Screen Image and the Waveform Data (useful for spreadsheets and data analysis).

c) Uncheck field Get waveform data to download only the Screen Image.

ECE Lab 

d) Select the Set I/O tab then Find Instruments button

54603B-intuilink-6 

 e) Select Identify Instrument(s) button

ECE Lab 

f) Set all RS232 settings as show below

Baud Rate = 19200 for all oscilloscope models.
Note Parity, Size, and HandShake settings that must be set appropriately! 

8-baud-19200 

g) The instrument found should display as shown below.

h) Select the Connect button

54603B-intuilink-7 

i) Instrument should be displayed as Connected. Select Close button.

54603B-intuilink-8 

j) Select the OK button

54621A_Connected_OK 

k) Oscilloscope will act frozen for a minute as the download of the screen image occurs. There is no Progress Bar to indicate it working.. 

l) When completed screen will be displayed within IntuiLink.

screen1 

m) Done

If any errors please proceed below. 

a) Try power cycling the scope and software. That sometime works.

 

2. Check Oscilloscope RS232 Settings for Model 54603B and 54645D  

The oscilloscope RS232 settings must match both the IO Connection Expert and IntuiLink Data Capture settings.

a) Select oscilloscope Utility button then select I/O Menu.

54603B-utility-iomenu
 

b) Set the correct Baud Rate and DTR setting for the connected oscilloscope.
Baud rate = 19200 for all oscilloscope models.
Handshaking = DTR for all oscilloscopes.
 

54603B_baud-dtr-b 

 

 

 

3. Check Agilent IO Control setup  

a) Click on the IO icon in your taskbar at the bottom right of your screen.

IOControlIcon2 

b) Select Agilent Connection Expert and wait one minute for application to start.

ConnectionExpertStart 

c) Close any welcome screens

d) Expand COM1 port to check instrument attached. Green check marks (as shown below) indicate proper communication.

54645D-COM1 

 
If the wrong instrument is displayed or there are red x-marks indicating an error, complete any of the following tests: 

(1) Check RS232 Cabling from PC to Oscilloscope.
(2) Power cycle the oscilloscope and wait until it is fully powered up and has completed self-tests, then
(3) Select Refresh All to check again.

Comlete Only If Needed:
(4) Select any instrument shown being attached to COM1 so that it is highlighed 
(2) Select Delete to delete instrument
(3) Select COM1 so that it is highlighed
(4) Check Baud rate and RS232 settings 
Baud rate = 19200 for all oscilloscope models.
Flow Control and all other RS232 settings should display as shown above.

(5) Select Add Instrument
(6) Select Auto-identify.

If errors, check cabling and oscilloscope RS232 settings in the sections above. 

 

 

 

 

 

CONTACT | PUBLIC SAFETY | CAREERS | RSS